Description
STAUNCH Mobile Crane
Beam
-Box beam Section L = 3000( Inner size)/ 3090 ( Center size ),
-Section size: 120x50x1.5×2.
-Box beam Drawing.
-According to FEM10.2.02, Beam deflection ≤L/200 (L—beam length) (uniform distributed load).
-Min. height of first beam is 189mm(beam top surface—ground).
-Beam level = 189 mm +Nx75mm (N=1,2,3,…) (see below
drawings).
-According to FEM10.2.02, Beam deflection ≤L/200 (L—beam length) (uniform distributed load).
-Min. height of first beam is 189mm(beam top surface—ground).
-Beam level = 189 mm +Nx75mm (N=1,2,3,….).
Technical Data
Storage Racking System | |
Beam’s length | 800×3 + 300mm = 2700mm ( Inner size ) |
Load per rack | 1000kg/Pallet x 3 pallet/level = 3000kg/ level |
Frame depth | H1200 -100mm = D 1100mm |
Frame height | 1500mm x 3 + 500 mm+ the gaps =H 5025mm |
Frame loading | 3000kg/ level x 3 levels= 9000kg |